HydroWorx 2000

Technical Specifications

Required Facility Services

A-C Power USA
Owner provided to HydroWorx Control panel, 120/208-230 volt, 200 amp, 3 phase, 3 wire with ground, 60 Hz, voltage regulation +/- 4%

Separate owner provided to 30 kW electric heater 120/208 - 230 volt, 100 amp, 3 phase, 3 wire with ground, 60 Hz, voltage regulation +/- 4%
Potable Water
1" or larger diameter supply with shutoff valve and anti-siphon device
Pool Room Size
Optimum 25' long by 19' wide by 10' high
Mechanical Room Size
Optimum 23' long by 19' wide by 9' high
Vertical Height of Mechanical Room Finished Floor to Pool Room Finished Floor
8' 5-5/8"

Equipment Specifications

Gallon Capacity
5,750 gallons
Pool Weight Empty
9,000 lbs
Pool Water Weight
50,000 lbs
Pool Weight Full
59,000 lbs
Overall Pool Size
13' long by 9' wide x 8' 6" deep
PH Level
7.2 - 7.8
Alkalinity Level
80 - 120 parts per million
Bromine Level
3.0 - 6.0 parts per million
Electric Heater (Gas Heat Available)

30 kW, heat rate 2º F per hour

Pool Water Temperature
High 94º F, low ambient